Wireless Probe Color Oled Display HLD Portable Hardness Tester
Place of Origin | Beijing |
---|---|
Brand Name | SADT |
Certification | CE ISO9001 SGS |
Model Number | HARTIP3210 |
Minimum Order Quantity | 1pc |
Price | USD400-1400/Pcs |
Packaging Details | Standard package |
Delivery Time | Within one week after receiving payment |
Payment Terms | T/T in advance, Western Union |
Supply Ability | 50pcs/week |

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xLanguage | 10 Language | Display | TFT Large Color LCD With Pixel 320 X 240 |
---|---|---|---|
Accuracy | +/-2 HLD | Testing Material | 11 Metal Materials |
Principle | Leeb Hardness Measurement | Probe | Cable Probe And Wireless Probe |
R/f Communication Distance | 10m In Space | Warranty | 1 Year |
Certificate | CE/ISO9001/SGS | ||
High Light | oled display portable hardness tester,wireless probe portable hardness tester,HLD Portable Hardness Tester |
Portable Rockwell Hardness Tester Accurate for Metal Materials HARTIP3210
HARTIP 3210 is a new generation of hardness tester with more advanced technology and features. The tester applies our new patent technology which makes the tester more accurate than old previous model. All impact device (probe) are no need to setup impact direction. HARTIP 3210can work with both analogy impact device and wireless RF probe.
The measuring values can be downloaded to PC and printer by wireless or by cable.
The HARTIP3210 also can be powered by USB power supply without battery via PC cable.
MEASURING METHOD
The measuring principle of HARTIP series hardness testers is defined as "the quotient of the impact body's rebound and impact velocity, multiplied by 1000." An impact body with a Tungsten Carbide test tip is propelled by spring force against the test surface and then rebounds back. A permanent magnet is contained within the impact body. When it passes through the coil on impact device, it induces an electric voltage which is proportional to the velocity of the impact body.
KEY FEATURES
- Wireless digital / cable analogue compatible
- No need to setup different impact direction
- Higher accuracy at+/-2 HLD
- TFT large color LCD with pixel 320 x 240
- Multi-color style – suitable under sunshine
- Multi display mode - statistics, bar graph, etc.
- Multi save mode for data
- Multi statistics calculation
- Print online and screen copy printout
- Sound reminder
- Real date and time
- Recalibration for unified or individual scale
- Operator, part no., procedure no. record
Specifications
Model | SADT HARTIP 3210 |
Principle | Leeb hardness measurement |
Accuracy | ±0.3% @ HL=800, Repeatability: ±2HL |
Display | 2.8” 320 x 240 TFT color LCD - fittable under sunshine |
Hardness scale | HL / HRC / HRB / HB / HV / HS / HRA /σb |
Measuring range | HL100-960 / HRC0.9-83.2 / HRB1-140 / HB1-1878 / HV1-1698 / HS0.5-1370 / HRA1-88.5 / σb(rm)1-6599N/mm² |
Probe | r/f wireless probe D / standard cable probe D DC / D+15 / C / G / E / DL (Optional) |
Materials | 11 common metal materials, 60 conversion curves |
Memory | 63 files, 100 data for each file, can be saved and re-readable |
Statistics function | Single group analysis -- mean, max., min., extreme deviation, standard deviation, coefficient of kurtosis, coefficient of skewness, percent of pass, column diagram, normality distribution test and uniform distribution test Double group analysis-- significant difference test for mean value, standard deviation, percent of pass and distribution |
Re-calibration | Calibration for unified or individual scale |
Indicator | Upper limit / Lower limit / low battery / buzzer warning / date and time |
Language | English, Simplified Chinese, Traditional Chinese, Russian, Korean, French, Italian, German, Turkish, Spanish |
Communication | USB / RS232 / Bluetooth / 2.4G wireless(Optional) |
Continous working time | >40 hours |
Power supply | 1.5V AA alkaline battery x 4 / 1.2V nickel-hydrogen rechargerable battery x 4 / 3.7VLi-ion rechargeable battery x 4 / USB power supply |
Working environment | -10~+45ºC |
Dimension (mm) | 195x84x38 |
Net weight (g) | 550 |
Standards | Conforming to ASTM A956, DIN 50156, GB/T 17394-1998 |
Special Features of Impact Devices
Type | Brief description | |
D |
Universal standard unit for majority of hardness testing assignments. |
|
DC | Extremely short impact device, other specs identical with type D. | |
Application: | - highly confined spaces | |
- holes and cylinders | ||
- internal measurements on assembled machines | ||
D+15 | Slim front section | |
Application: | - grooves and recessed surfaces. | |
DL | Extremely slim front section | |
Application: | - extremely confined spaces | |
- base of grooves | ||
C | Reduced impact energy ( compared with type D). | |
Application: | - surface hardened components, coatings | |
- minimum layer thickness: 0.2mm. | ||
- thin walled or impact sensitive components (small measuring indentation). | ||
E | Synthetic diamond test tip (approx.5000 HV). | |
Application: | - extremely high hardness measurement such as high carbon steel up to 1200 HV | |
G | Increased impact energy(approx. 9 times that of type D) | |
Application: | - Brinell hardness range only | |
- heavy cast and forged parts with lower demands on surface finish. |