Portable Hardness Tester
-
Portable Leeb Hardness Tester
-
Hardness Tester
-
Ultrasonic Thickness Gauge
-
Concrete Test Hammer
-
Brinell Hardness Testing
-
Rockwell Hardness Tester
-
Vickers Hardness Tester
-
Gloss Meter
-
Color Difference Meter
-
Metallurgical Microscope
-
Surface Roughness Tester
-
Ultrasonic Flaw Detector
-
Portable Vibration Meter
-
Paul FrameThank you very much for all your help regarding the SADT Concrete Hammer and hardness tester which are working well and we are very pleased with it.
Eco-Friendly Digital Portable Vibration Meter With Digits Liquid Crystal Display
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xVelocity | 0.01~19.99 Cm/s (r.m.s. Value) | Power Supply | 6F22 9V Laminated Cell |
---|---|---|---|
Dimension | 185mm×68mm×30mm | Net Weight | 200g |
Displacement | 0.001~1.999 Mm (peak To Peak) | Acceleration | 0.1~199.9 M/s2 (peak Value) |
Vibration Acceleration | ≤ 199.9 M/s2 (peak Value) | ||
High Light | vibration measurement equipment,vibration monitoring equipment |
Eco-Friendly Digital Portable Vibration Meter With Digits Liquid Crystal Display
Vibration transducer:
Annular shear type acceleration transducer (only for integral type)Separate, built-in electric charge amplifier,
shear type acceleration transducer (only for separate type)
Temperature transducer:
Type K thermoelectro couple transducer (only for EMT220 with temperature measuring function)
Detector:
Root Mean Square
Vibration measurement scale:
Displacement: 0.001~1.999 mm (peak to peak)
Velocity: 0.01~19.99 cm/s (r.m.s. value)
Acceleration: 0.1~199.9 m/s2 (peak value)
Vibration acceleration: ≤ 199.9 m/s2 (peak value)
Temperature measurement scale:
-20 ~400 ℃(only for EMT220 with temperature-measuring
function)
Accuracy:
Vibration measurement: ±5%Measurement value; ±2 Digits
Temperature measurement: ±1% Measurement value; ±1 Digit
Vibration Frequency Range:
10 ~1 kHz (Normal type)
5 ~1 kHz (Low frequency type)
1 ~15 kHz (only at “HI” position for acceleration)
Display: Digits liquid crystal display
Sample period:1 second
Vibration measurement value readout:
Displacement: Peak to peak value (r.m.s.×2√2)
Velocity: Root mean square (r.m.s.)
Acceleration: Peak value (r.m.s.x√2)
Readout-keeping function:
Readout of vibration / temperature value can be remembered after
releasing the Measure Key (Vibration / Temperature Switch)
Output Signal:
2V AC (peak value) (load resistance above 10 kΩ at full measuring scale)
Power supply:
6F22 9V laminated cell
Power on / off:
Battery life about 30 hours for continuous use
Power up when pressing Measure Key (Vibration / Temperature Switch)
Power automatically shut off after releasing the Measure Key for one minute
Operating condition:
Temperature: 0 ~50 ℃
Humidity: ≤ 90% RH
Volume:
185 mm×68 mm×30 mm
Weight:200g
Vibration transducer:
Annular shear type acceleration transducer (only for integral type)Separate, built-in electric charge amplifier, shear type acceleration transducer (only for separate type)
Temperature transducer:
Type K thermoelectro couple transducer (only for EMT220 with temperature measuring function)
Detector:
Root Mean Square
Vibration measurement scale:
Displacement: 0.001~1.999 mm (peak to peak)
Velocity: 0.01~19.99 cm/s (r.m.s. value)
Acceleration: 0.1~199.9 m/s2 (peak value)
Vibration acceleration: ≤ 199.9 m/s2 (peak value)
Temperature measurement scale:
-20 ~400 ℃(only for EMT220 with temperature-measuring function)
Accuracy:
Vibration measurement: ±5%Measurement value; ±2 Digits
Temperature measurement: ±1% Measurement value; ±1 Digit
Vibration Frequency Range:
10 ~1 kHz (Normal type)
5 ~1 kHz (Low frequency type)
1 ~15 kHz (only at “HI” position for acceleration)
Display: Digits liquid crystal display
Sample period:1 second
Vibration measurement value readout:
Displacement: Peak to peak value (r.m.s.×2√2)
Velocity: Root mean square (r.m.s.)
Acceleration: Peak value (r.m.s.x√2)
Readout-keeping function:
Readout of vibration / temperature value can be remembered after
releasing the Measure Key (Vibration / Temperature Switch)
Output Signal:
2V AC (peak value) (load resistance above 10 kΩ at full measuring scale)
Power supply:
6F22 9V laminated cell
Power on / off:
Battery life about 30 hours for continuous use
Power up when pressing Measure Key (Vibration / Temperature Switch)
Power automatically shut off after releasing the Measure Key for one minute
Operating condition:
Temperature: 0 ~50 ℃
Humidity: ≤ 90% RH
Volume:
185 mm×68 mm×30 mm
Weight:200g
Standard Package - EMT220 | |
EMT220 main unit | 1 |
Short feeler lever (only for integrated type) | 1 |
Acceleration transducer (only for separate type) | 1 |
Transducer connection cable (only for separate type) | 1 |
Thermo electro couple transducer (only for EMT220 with temperature measuring function) |
1 |
6F22 cell | 1 |
Operation manual | 1 |
Carrying case | 1 |